ÄÁÅÙÃ÷»ó¼¼º¸±â

SIMULINKÀ» È°¿ë ÀûÀÀÇü ·Îº¿ ÀüÀÚ±âÆÄ ±â¹Ý ±ÙÀ° ÇÇ·Î »ç¿ë¿¡ ´ëÇÑ ¿¬±¸
SIMULINKÀ» È°¿ë ÀûÀÀÇü ·Îº¿ ÀüÀÚ±âÆÄ ±â¹Ý ±ÙÀ° ÇÇ·Î »ç¿ë¿¡ ´ëÇÑ ¿¬±¸
  • ÀúÀÚAzeemsha Thacham PoyilID, Volker Steuber, Farshid Amirabdollahian Àú
  • ÃâÆÇ»ç¾ÆÁø
  • ÃâÆÇÀÏ2020-07-14
  • µî·ÏÀÏ2020-12-21
º¸À¯ 1, ´ëÃâ 0, ¿¹¾à 0, ´©Àû´ëÃâ 8, ´©Àû¿¹¾à 0

Ã¥¼Ò°³

Studies on improving the adaptability of upper limb rehabilitation training do not often
consider the implications of muscle fatigue sufficiently. In this study, electromyogram
features were used as fatigue indicators in the context of human-robot interaction. They
were utilised for auto-adaptation of the task difficulty, which resulted in a prolonged
training interaction. The electromyogram data was collected from three gross-muscles of
the upper limb in 30 healthy participants. The experiment followed a protocol for
increasing the muscle strength by progressive strength training, that was an
implementation of a known method in sports science for muscle training, in a new domain
of robotic adaptation in muscle training. The study also compared how the participants in
three experimental conditions perceived the change in task difficulty levels. One task
benefitted from robotic adaptation (Intervention group) where the robot adjusted the task
difficulty. The other two tasks were control groups 1 and 2. There was no difficulty
adjustment at all in Control 1 group and the difficulty was adjusted manually in Control 2
group. The results indicated that the participants could perform a prolonged progressive
strength training exercise with more repetitions with the help of a fatigue-based robotic
adaptation, compared to the training interactions, which were based on manual/no
adaptation. This study showed that it is possible to alter the level of the challenge using
fatigue indicators, and thus, increase the interaction time. The results of the study are
expected to be extended to stroke patients in the future by utilising the potential for
adapting the training difficulty according to the patient¡¯s muscular state, and also to
have a large number repetitions in a robot-assisted training environment.

¸ñÂ÷

Á¦ 1Æí : SIMULINK ±âº»Æí
1.1 SIMULINKÀÇ ½ÃÀÛ 1
ºí·ÏÀÇ ¿¬°á 5
ºí·Ï ÆĶó¹ÌÅÍÀÇ ¼³Á¤ 7
½Ã¹Ä·¹À̼ǠÆĶó¹ÌÅÍ (Configuration Parameters)ÀÇ ¼³Á¤ 8
½Ã¹Ä·¹À̼ÇÀÇ ¼öÇà 9
ºí·Ï ÆĶó¹ÌÅÍÀǠǥ½Ã 9
º¹¼ö µ¥ÀÌÅÍÀǠǥ½Ã 11
2.2 µ¿Àû ½Ã¹Ä·¹À̼Ǡ13
ÀÌÂ÷ ¹ÌºÐ¹æÁ¤½Ä 17
¼±Çü »óź¯¼ö ¸ðµ¨ 23
DC ¸ðÅÍÀÇ ½Ã¹Ä·¹À̼Ǡ24
ÇÔ¼ö ºí·ÏÀÇ »ç¿ë 29
Â÷ºÐ¹æÁ¤½Ä(difference equation)ÀÇ ¸ðµ¨¸µ 34
Subsystem(ºÎ½Ã½ºÅÛ)ÀÇ ±¸¼º 37
Á¦ 2Æí : ¿¬±¸³í¹®
Adaptive robot mediated upper limb training using
electromyogram-based muscle fatigue indicators
1. Introduction 41
2. Materials and methods 44
3. Experimental protocol and methods 45
4. Robotic resistance adaptation 56
5. Task performance measures 59
6. Experimental Results 57
7. Conclusions 69
8. References 70

ÇÑÁÙ ¼­Æò